ATEX sensors for hazardous areas

Intrinsically safe temperature sensors under our own certification — resistance thermometers and thermocouples, made in Hanau.

ATEX sensors measure temperature where flammable gases, vapours or dusts may occur: in chemicals and petrochemicals, painting and drying plants, mills, silos and spray booths. GHI manufactures intrinsically safe Pt100 resistance thermometers and type K, N and J thermocouples for zones 0, 1 and 2 as well as zones 20, 21 and 22. The EU type-examination certificate is issued to GHI — we mark our products ourselves, issue the declaration of conformity ourselves and do not depend on any subcontractor for the Ex version.

Our certification — and what it covers

GHI is itself an ATEX manufacturer. The EU type-examination certificate and the IECEx certificate are issued to GHI, and production is monitored by notified body 2004 (Bureau Veritas). The approval covers the WME and TME measuring inserts and the WML and TML sheathed sensors — on their own and installed in our thermowells and connection heads.

Certificates and parameters

EPS 25 ATEX 1 060 X, Rev. 1 · IECEx EPS 25.0012X, Issue 1 · Cable sensors WKF: IBExU 10 ATEX 1062 X (Ex eb/tb)

  • Without thermowell: II 1G Ex ia IIC T1…T6 Ga · II 2G Ex ib IIC T1…T6 Gb · II 2D Ex ib IIIC T440 °C…T63 °C Db
  • With thermowell: II 1/2G Ex ib IIC T1…T6 Ga/Gb · II 1/2D Ex ib IIIC T200 440 °C…T200 63 °C Da/Db
  • Measuring range in the hazardous area −50 … +450 °C · ambient temperature at the connection head −40 … +85 °C
  • Intrinsic safety parameters: Ui 30 V · Ii 70 mA · Pi 500 mW (total over all contacts) · Ci 250 pF/m · Li 50 µH/m
  • Standards: EN IEC 60079-0:2018 · IEC 60079-11:2023 · EN IEC 60079-26:2024

Not covered are flameproof enclosures (Ex d) and process temperatures above +450 °C. Tell us the zone, equipment group and temperature class and we will design the version.

Which version suits your zone?

Zone and installation determine the type of protection and the marking. Choose the row that matches your measuring point.

ApplicationVersionMarkingResistance
thermometer
Thermocouple
Zone 0 — gas continuously or for long periodsMeasuring insert or sheathed sensor without thermowell, type of protection Ex iaII 1G Ex ia IIC T1…T6 GaSheathed sensors →Sheathed thermocouples →
Zone 1 — gas occasionallyThe same sensors in type of protection Ex ibII 2G Ex ib IIC T1…T6 GbMeasuring inserts →Measuring inserts →
Sensor in zone 0, connection head in zone 1Measuring insert in thermowell, installed in the partition wallII 1/2G Ex ib IIC T1…T6 Ga/GbThermowell thermometers →Thermowell thermocouples →
Zone 21 — combustible dustMeasuring insert or sheathed sensor without thermowellII 2D Ex ib IIIC T440 °C…T63 °C DbSheathed sensors →Sheathed thermocouples →
Zone 20/21 — dust, installed in the partition wallMeasuring insert in thermowellII 1/2D Ex ib IIIC T200 440 °C…T200 63 °C Da/DbThermowell thermometers →Thermowell thermocouples →
Measurement on the pipeline, permanently connected cableWKF cable sensor in increased safetyType of protection Ex eb / tb to IBExU 10 ATEX 1062 XCable sensors →–

ATEX versions at a glance

RESISTANCE THERMOMETER · MEASURING INSERT

WME — resistance thermometer measuring insert

Spring-loaded and replaceable for existing thermowells, with terminal block, stranded wires or head-mounted transmitter.

without thermowell: II 1G Ex ia IIC T1…T6 Ga
in thermowell: II 1/2G Ex ib IIC T1…T6 Ga/Gb

Ø 3.0 / 6.0 mm · 1× or 2× Pt100 · Ex ia and Ex ib

To the measuring inserts →

RESISTANCE THERMOMETER · SHEATHED SENSOR

WML — sheathed resistance thermometer

Mineral-insulated sheath, bendable, fast response. With connecting cable, free ends or connector.

II 1G Ex ia IIC T1…T6 Ga
II 2G Ex ib IIC T1…T6 Gb
II 2D Ex ib IIIC T440 °C…T63 °C Db

Ø 1.0–6.0 mm · stranded wires, LEMO, M12

To the sheathed sensors →

THERMOCOUPLE · MEASURING INSERT

TME — thermocouple measuring insert

Sheathed measuring insert type K or N for existing thermowells, spring-loaded and replaceable.

without thermowell: II 1G Ex ia IIC T1…T6 Ga
in thermowell: II 1/2G Ex ib IIC T1…T6 Ga/Gb

Ø 3.0 / 6.0 mm · 1× or 2× element

To the measuring inserts →

THERMOCOUPLE · SHEATHED SENSOR

TML — sheathed thermocouple

Bendable sheathed sensor type K, N or J, measuring junction insulated or grounded.

II 1G Ex ia IIC T1…T6 Ga
II 2G Ex ib IIC T1…T6 Gb
II 2D Ex ib IIIC T440 °C…T63 °C Db

Ø 1.0–6.0 mm · stranded wires, thermocouple connector, LEMO, M12

To the sheathed thermocouples →

RESISTANCE THERMOMETER · WITH THERMOWELL

Ex thermowell resistance thermometers

Eleven designs to DIN 43772 for screwing in, welding in or with flange — with certified WME measuring insert and Ex connection head.

II 1/2G Ex ib IIC T1…T6 Ga/Gb
II 1/2D Ex ib IIIC T200 440 °C…T200 63 °C Da/Db

Ø 6–14 mm · head form B, DAN/BUZ

Choose a design →

THERMOCOUPLE · WITH THERMOWELL

Ex thermowell thermocouples

The same eleven designs as thermocouples — with certified TME measuring insert and Ex connection head.

II 1/2G Ex ib IIC T1…T6 Ga/Gb
II 1/2D Ex ib IIIC T200 440 °C…T200 63 °C Da/Db

Ø 6–14 mm · type K, N or J

Choose a design →

INCREASED SAFETY

WKF — cable sensor in Ex eb/tb

Sensor tip with permanently attached cable, for plant and machinery in hazardous areas.

Type of protection Ex eb / tb
to IBExU 10 ATEX 1062 X

Ø 2.5–6.0 mm · silicone, PTFE, glass fibre

To the cable sensors →


Understanding ATEX — the basics in brief

Zones, equipment categories and EPL

The zone describes how often an explosive atmosphere occurs and thus determines which equipment category may be installed:

  • Gas: zone 0 (continuous) → category 1G, EPL Ga · zone 1 (occasional) → 2G, Gb · zone 2 (rare, short-term) → 3G, Gc
  • Dust: zone 20 → 1D, Da · zone 21 → 2D, Db · zone 22 → 3D, Dc
  • Equipment for zone 0 may always be used in zones 1 and 2 as well, but not the other way round

Type of protection intrinsic safety: Ex ia and Ex ib

Intrinsic safety limits the energy in the circuit so far that neither a spark nor heating can cause ignition. Ex ia is approved for zone 0, Ex ib for zone 1. The sensor alone does not make the measuring point intrinsically safe: it must be connected to a certified intrinsically safe circuit, i.e. an isolating repeater, Zener barrier or transmitter with intrinsically safe input.

Reading the marking — example II 1/2G Ex ib IIC T4 Ga/Gb

Every symbol has a meaning, and this is exactly what the operator checks:

  • II — equipment group for all areas except mining
  • 1/2G — partition-wall installation: the tip is in zone 0, the connection head in zone 1
  • Ex ib — type of protection intrinsic safety
  • IIC — highest explosion group, includes hydrogen and acetylene
  • T4 — temperature class: maximum surface temperature 135 °C
  • Ga/Gb — equipment protection level inside/outside the partition wall

Intrinsic safety parameters and the verification

For verifying intrinsic safety, the sensor parameters are compared with the values of the isolating repeater: Ui 30 V, Ii 70 mA and Pi 500 mW apply as the total over all contacts — with two measuring elements, therefore combined, not per circuit. In addition, the cable-length-dependent values Ci 250 pF/m and Li 50 µH/m apply. On request we prepare the intrinsic safety verification to EN IEC 60079-11, section 5.7, as a test document for your records.

Temperature class and surface temperature

The maximum surface temperature results from ambient temperature and supplied power. For the dust zones the marking is T440 °C…T63 °C, with thermowell as a T200value. The ambient temperature at the connection head may be between −40 and +85 °C, the measuring range of the sensor in the hazardous area between −50 and +450 °C.

Special conditions for safe use

The certificate carries the suffix X. Three points must be observed during installation and operation:

  • For installation in a partition wall to zone 0 or 20, an additional thermowell is required
  • The process connection must be leak-tight
  • The metal housing must be earthed via the installation

What we do not offer

Being clear saves a query: our approval covers only the type of protection intrinsic safety “i”. We do not offer flameproof enclosures (Ex d), and the approval ends above +450 °C process temperature. As a rule we do not use third-party certificates — what is on our type plate is our own certificate.

What is supplied with the sensor

Every Ex sensor comes with a type plate with full marking, EU declaration of conformity and operating instructions. On request we add factory calibration with test report, inspection certificate and the intrinsic safety verification. Please state the required scope directly in your enquiry.

Approved and made in Hanau

GHI has been building temperature sensors since 1970 and manufactures at its Hanau site. Ex production runs under a quality assurance system monitored by Bureau Veritas, and the company is certified to ISO 9001. As a result, Ex versions add no extra lead time compared with the standard version.

No hazardous area?

We supply the same designs without Ex approval too — with the same configurator and the same lead times.

To the resistance thermometers →To the thermocouples →

Typical industries

Chemicals & petrochemicals Pharma & biotechnology Food & beverages Plastics & extrusion Energy, power plants & hydrogen Machinery & plant engineering

Please contact us

We are happy to help with questions about products, versions and delivery times.

Dennis Kühne
Phone: +49 6181 504 93 18
Mobile: +49 160 91437153
E-mail: info@ghi-gmbh.de

Dennis Kühne, Sales

Zones, types of protection and marking explained

What Ex ia, Ex ib and Ex eb mean, which zone requires which equipment category, how to read a type plate — and which of our versions is approved where.

To the technical page on explosion protection →