Skip to main content Skip to search Skip to main navigation

Compensating cables

34 versions for types B, J, K, L, N and S to DIN EN 60584 — from PVC to glass fibre, −60 °C to +400 °C.

The compensating cable extends the thermocouple to the reference junction. Its cores are not made of the thermocouple material itself but of cheaper alloys with the same thermoelectric voltage up to around +200 °C. That is enough as long as the cable itself does not get hot — and makes the connection considerably cheaper than a thermocouple cable.

If the cable itself gets warm, or if it is to hold the same accuracy over the whole range, a thermocouple cable belongs at the measuring point instead.

Technical data

Thermocouple pairsTyp B, J, K, L, N, S · IEC / DIN EN 60584
Number of cores2- and 4-core
Cross-sections0,22 · 0,5 · 0,75 · 1,0 · 1,5 mm²
Insulation and sheathPVC, silicone, FEP, PFA, glass fibre
ShieldCu braid or foil shield, without on request
Armouringsteel braid or stainless steel braid
Operating temperature−60 … +400 °C, depending on material
Core identificationto DIN EN 60584-3

All 34 versions in the cable finder →

Filter by type, number of cores, cross-section, insulation material, shield and operating temperature · data sheet for each version

Back to the overview Cables · All versions are sold by the metre, assembled on request · price on request.