Connection heads
Forms A to XI-DSNW — aluminium, plastic and ATEX, with cable entry M20, NPT or PG and process connection M24, G ½" or tube Ø.
The connection head holds the terminal block or the transmitter and closes the measuring point off to the outside. Its two dimensions decide whether it fits: the cable entry towards the cable and the process connection towards the thermowell or the sensor. Both are given for every version in the finder.
We supply the heads on their own, with a matching terminal block or complete on the finished thermometer. Programmed transmitters we fit directly on request.
All versions in the head finder →
Filter by form, cable entry, process connection, closure and material · with the former article number for repeat orders
Aluminium — the standard forms

Round head · lid
Form A / AA
The classic to DIN 43729
Screw-on lid · terminal block 33/46 mm · process connection M24, Ø 22.5 or Ø 32.5

Flat · lid
Form B
Low overall height
Also in stainless steel and in a tall version · M24, G ½", Ø 15.5

Hinged lid · screw
Form DA / DAW
Head with hinged lid
Lid stays on the head · screw or clip · DAW with a taller lid for transmitters

Hinged lid · large
Form DAN / DANW
The largest standard head
Room for transmitter and terminal block · DANW with a tall lid · M24, Ø 15.5, Ø 22.5, G ½"

Twin · 2×M20
Form AD / DAND
Two cable entries
For two measuring circuits or loop-through wiring

M16 · small
Form MA / NAA
Smallest head
M16×1.5 to M10×1 · for screw-in sensors with little space
Plastic
Light, corrosion-resistant and cheaper than aluminium — polyamide, black.

Polyamide · hinged lid
Form DSN / DSNW
Plastic head
PA, black · DSNW with a tall lid · M20×1.5 to M24 or Ø 15.3
ATEX
For potentially explosive areas — intrinsic safety (Ex i), increased safety (Ex e) and flameproof enclosure (Ex d).

Ex i · intrinsically safe
Form XI-DSN / XI-DSNW
Plastic, intrinsically safe
PA, black · for intrinsically safe circuits · also with cable gland

Ex d · flameproof
Form XD-AD
Flameproof enclosure
M20×1.5 to M24 · Ex nA version available
Which head fits?
| Your requirement | Matching form |
|---|---|
| Standard thermometer to DIN 43729 | A or AA |
| Little installation height | B |
| Transmitter has to fit inside | DAN, DANW or DAW — tall lid |
| Lid must not get lost | DA, DAW, DAN, DANW — hinged lid |
| Two cable entries | AD or DAND |
| Corrosive environment, low weight | DSN or DSNW (polyamide) |
| Intrinsically safe circuit (Ex i) | XI-DSN or XI-DSNW |
| Zone 1, increased safety | XE-DANA |
| Flameproof enclosure (Ex d) | XD-AD |
| Screw-in sensor, very little space | MA |
Tell us the form, cable entry and process connection — or simply quote the old article number you have ordered before. info@ghi-gmbh.de · +49 6181 504 93 18