Skip to main content Skip to search Skip to main navigation

APAQ-C130 — INOR

Programmable head-mounted transmitter for Pt100 and Ni100 — the economical solution when 4…20 mA is enough.

INOR APAQ-C130

Small, programmable, without HART: the APAQ-C130 takes a Pt100 or Ni100 in a 2-, 3- or 4-wire connection and outputs 4…20 mA. On sensor break or short circuit the signal goes to ≤ 3.6 mA — so the control room detects the fault immediately.

It has no galvanic isolation. Where that is needed, we use the IPAQ-C330.

Technical data

InstallationConnection head
InputPt100 and Ni100 in a 2-, 3- or 4-wire connection
Output4…20 mA
Galvanic isolationnone
Supply voltage6…32 V DC
Sensor break / short circuit≤ 3,6 mA
Programmingto the measuring range you want, by us before delivery

Versions in our stock

GHI article numberVersion
HMUAPAQC130RT00Pt100 / Ni100, programmable, 4…20 mA (INOR 70C130011)
70R4600010APAQ-C130 RTD — digital head transmitter for Pt100
70C1300211APAQ-C130 TC — version for thermocouples

Enquire about the APAQ-C130

We configure and programme the transmitter to your measuring range — tell us the sensor, range and output. info@ghi-gmbh.de or +49 6181 504 93 18

Back to the overview Temperature transmitters · We carry out programming and calibration in our own laboratory .