The TH320 sits in the sensor's connection head and converts the sensor signal into 4…20 mA right there — the cable to the control cabinet then carries an interference-proof current signal instead of a sensitive thermoelectric voltage. One input, one galvanically isolated two-wire output, configuration via HART.

We supply it fitted and programmed to your measuring range, together with the sensor, connection head and thermowell — or separately as a spare part.

Technical data

InstallationForm B connection head to DIN 43729
Input1 × Pt100 to IEC 60751 in a 2-, 3- or 4-wire connection · thermocouple · resistance · voltage
Output4…20 mA, two-wire, galvanically isolated · HART
Functional safetyIEC 61508 SIL 2/3
Explosion protectionATEX / IECEx: II 1 G Ex ia IIC T6…T4 Ga · II 3 G Ex ec IIC T6…T4 Gc · II 1 D Ex ia IIIC · further approvals CSA, FM, NEPSI, Inmetro, UKEX
Accessories4-core silicone cable set for Pt100 (2 × red / 2 × white)

Versions in our stock

GHI article numberVersion
HMU7NG03100BA00HART, SIL, Ex — Pt100 3-wire (7NG0310-0BA00-0NA0-Z)
HMU7NG03100CA00HART, SIL, Ex — Pt100 4-wire
HMU7NG03100BA01HART, SIL — without Ex (7NG0310-0BA00-0AA0-Z)
HMU7NG03100BA03HART — basic version (7NG0310-0BA00-0AA0)
HMU7NG03200JA004…20 mA, galvanically isolated, Pt100 and thermocouple