iTEMP TMT82 — Endress+Hauser
Head transmitter with HART 7, SIL 2 and ATEX — our largest stock item among the transmitters.

The TMT82 takes a thermocouple or Pt100 and outputs 4…20 mA with HART, input and output galvanically isolated. It is certified for safety-related applications to SIL 2 and, in the Ex version, approved for zone 0 and zone 1.
It is available with screw terminals and with push-in terminals — the latter save time in the connection head, because the core is simply pushed in.
Technical data
| Installation | Form B connection head to DIN 43729, also a DIN rail adapter |
| Input | Thermocouple · Pt100 · resistance · voltage, one or two sensors |
| Output | 1 × 4…20 mA · HART protocol |
| Galvanic isolation | ja |
| Functional safety | SIL 2 |
| Explosion protection | ATEX II 1 G Ex ia IIC T4/T5/T6 · ATEX II 2 G Ex ia IIC T4/T5/T6 |
| Terminals | Screw terminals or push-in |
Versions in our stock
| GHI article number | Version |
|---|---|
| HMUTMT828NMO220 | HART, SIL 2 — without Ex (TMT82-9AJ2/1D7) |
| HMUTMT8279N5220 | HART, SIL 2, ATEX (TMT82-BAA2AB1A1AAA1) |
| HMUTMT8279N5221 | HART, SIL 2, ATEX, push-in terminals (TMT82-BAA1AB1A1AAA1+LA) |
Enquire about the iTEMP TMT82
We configure and programme the transmitter to your measuring range — tell us the sensor, range and output. info@ghi-gmbh.de or +49 6181 504 93 18
Back to the overview Temperature transmitters · We carry out programming and calibration in our own laboratory .