Miniature sheathed thermocouples from Ø 0.5 mm
Miniature sheathed thermocouples with Ø 0.5 and 1.0 mm measure where no other sensor fits: in narrow bores, in tools, on test benches and in laboratory set-ups. Their low mass gives very short response times and hardly disturbs the measuring point.
The thermocouple wires are mineral-insulated inside a bendable metal sheath. We make miniature sheathed thermocouples in Hanau, Germany, with connecting cable, with mini thermocouple plug or with free ends – thermocouple to IEC 60584-1, measuring junction isolated or grounded, class 1 or 2. You define length and connection.
From 1 piece · special lengths to your specification · standard versions approx. 2 weeks, custom builds on request
Enquire about a miniature sheathed thermocouple
Put together diameter, thermocouple, length and connection in the configurator – the enquiry comes straight to us. Or describe your measuring point to us.
Choose and configure your version
Three designs available from Ø 0.5 mm. They differ in the connection. The type page shows the dimension drawing, technical data and data sheet; the configurator contains the complete order key. Choose by your installation situation.

with cable
TML
Sheath with transition sleeve and thermocouple or compensating cable, mini thermocouple plug at the cable end on request.
Ø 0.5 / 1.0 / 1.6 / 2.0 mm (up to 6.0 mm)

free ends
TMT
Without connecting cable, free ends 10, 20 or 30 mm – for installation in your own assemblies and series parts.
Ø 0.5 / 1.0 / 1.5 / 1.6 / 2.0 mm (up to 8.0 mm)

with plug
TMS
Mini or standard thermocouple plug or socket fitted directly to the sheath, in the standardised colour – for a quick sensor change.
Ø 0.5 / 1.0 / 1.5 / 1.6 / 2.0 mm (up to 6.0 mm)
Diameters by type
Selectable diameters according to the order key in our catalogue. Other diameters can be requested via the “other” option in the configurator.
| Type | Connection | Ø 0.5 | Ø 1.0 | Ø 1.5 / 1.6 | Ø 2.0 | further Ø | Sheath material | Thermocouple |
|---|---|---|---|---|---|---|---|---|
| TML | cable, free ends, mini or standard thermocouple plug, LEMO | ● | ● | 1.6 | ● | 3.0 / 6.0 mm | Inconel 600 (K, N), 1.4571 (J) | 1 × / 2 × type K, N, J · 1 × type S |
| TMT | free ends 10 / 20 / 30 mm | ● | ● | ● | ● | 3.0 / 6.0 / 8.0 mm | 1.4571 / 316Ti, 1.4404 / 316L, Inconel 600 / 2.4816 (K, N) | 1 × / 2 × type K, N · 1 × type J · type S on request |
| TMS | mini or standard thermocouple plug or socket | ● | ● | ● | ● | 3.0 / 6.0 mm | 1.4571 / 316Ti, Inconel 600 / 2.4816 (K, N) | 1 × / 2 × type K, N · 1 × type J · type S on request |
| TML-EX | cable, ATEX / IECEx | – | – | – | – | 3.0 / 6.0 mm only | Inconel 600 (K, N), 1.4571 (J) | 1 × / 2 × type K, N, J · 1 × type S |
● available · – not available. We check with your enquiry which combination of thermocouple type, duplex version and sheath material is possible at Ø 0.5 mm. Explosion-protected sheathed thermocouples are not available as miniature versions: the TML-EX is certified for Ø 3 or 6 mm only.
Where miniature sheathed thermocouples are used
Test benches and vehicle testing
Short response time for fast temperature changes, mini thermocouple plug for frequent sensor changes. One example is our TAM-4 brake disc thermocouple with a Ø 0.5 mm sheathed tip. More sensors under Test benches and automotive.
Laboratory and measurement
The low mass draws hardly any heat from the sample. With free ends (TMT) the sensor connects to your own terminals and instruments, with a plug (TMS) to existing thermocouple sockets.
Narrow bores and tools
From Ø 0.5 mm the sheathed thermocouple fits into tools, bearing bores, nozzles and your own assemblies. The sheath can be bent to suit the installation space.
What matters with small diameters
- Measuring junction: Grounded, the thermocouple is welded to the sheath tip and responds faster. Isolated, it is electrically separated from the sheath and immune to interference. If in doubt, we recommend isolated.
- Temperature: With sheathed thermocouples the upper limit is usually set by the sheath material, not by the thermocouple. Tell us the continuous and peak temperature and we will design the version accordingly.
- Plug and cable: The thermocouple plug withstands about +200 °C, the connecting cable – depending on its insulation – less than the tip. Plug and transition sleeve therefore belong outside the hot zone.
- Accuracy: Class 1 or 2 to IEC 60584-1. The tolerances per type are listed under Thermocouple types.
- Documents: Inspection certificate 3.1 to EN 10204, factory calibration certificate and RoHS declaration on request.
All diameters, types and connections at a glance: Sheathed thermocouples · Basics: Choosing a sheathed sensor · Pt100 or thermocouple?
Please contact us
We are glad to help with questions about products, versions and delivery times.
From 1 piece · special lengths to your specification · standard versions approx. 2 weeks, custom builds on request · inspection certificate 3.1 to EN 10204, factory calibration certificate and RoHS declaration on request.
Drawing or photo of the type plate? Just e-mail it to info@ghi-gmbh.de.
Dennis Kühne
Phone: +49 6181 5049318
Mobile: +49 160 91437153
E-mail: info@ghi-gmbh.de