TET-3G — screw-in thermocouple form 3G
tapered tip · with neck tube · DIN 43772

Dimension drawing · dimensions in mm · binding dimensions per order confirmation
Screw-in thermometer with neck tube and a conically tapered thermowell for fast heat transfer. With a tantalum coating for highly corrosive media on request.
- Process plants requiring a short response time
- Chemicals and pharmaceuticals
- Heat exchangers and circuits
- Tip Ø 6 / 9 / 11 mm
- Screw-in boss G 1/2" … G 1", NPT
- Tantalum coating optional
- Successor to the Schramm series T31 — identical installation dimensions
Put a version together and enquire
13 positions from the order key in our catalogue. The configurator shows the type code as you go and sends the enquiry straight to us.
Prefer the phone? +49 6181 504 93 18 · info@ghi-gmbh.de
Technical data
II 1/2G Ex ib IIC T1…T6 Ga/Gb
II 1/2D Ex ib IIIC Da/Db.
Sensor −50…+450 °C, connection head −40…+85 °C.
Data sheets, ATEX certificates and operating instructions in the download centre
Typical industries
The TET-3G is used mainly in these fields. The assignment names the most common applications and does not exclude others — talk to us if your application is not listed.
Chemicals & petrochemicals
Pharmaceuticals & biotechnology
Food & beverages
Energy, power plants & hydrogen
Mechanical & plant engineering
Heating, ventilation, refrigeration & buildings
Up to +600 °C: the same design as a resistance thermometer WEK-3G — to the Pt version
Please contact us
We are glad to help with questions about products, versions and delivery times.
Dennis Kühne
Phone: +49 6181 504 93 18
Mobile: +49 160 91437153
E-mail: info@ghi-gmbh.de