RKR-C799 — ceramic thermowell C 799 to DIN EN 50446
Alumina > 99 % Al₂O₃ · gas-tight · up to +1,650 °C · Ø 8 – 24 mm

Dimension drawing · dimensions in mm · binding dimensions per order confirmation
Gas-tight ceramic thermowell of high-purity alumina for furnace, melting and firing processes. C 799 can be used up to +1,650 °C and is mandatory with noble-metal thermocouples because it protects the thermocouple wires from contamination. Four diameters are available from stock.
- Industrial furnaces, hardening and annealing furnaces
- Glass, ceramic and foundry industries
- Combustion and exhaust gas processes
- Inner thermowell for TSK and TSM-1 thermocouples
- Alumina > 99 % Al₂O₃, gas-tight
- Temperature-resistant up to +1,650 °C
- Ø 8 / 10 / 15 / 24 mm from stock
- Special lengths cut from standard tubes
Put a version together and enquire
4 positions from the order key in our catalogue. The configurator shows the type code as you go, checks the combination for plausibility and sends the enquiry straight to us.
You generate the data sheet for the chosen version in the configurator with "Create PDF". Prefer the phone? +49 6181 504 93 18 · info@ghi-gmbh.de
Technical data
Available lengths per diameter
| Ø D × wall s | 375 mm | 530 mm | 740 mm | 1.030 mm | 1.430 mm | 2.030 mm |
|---|---|---|---|---|---|---|
| 8,0 × 1,5 mm | • | • | • | • | • | • |
| 10 × 2,0 mm | • | • | • | • | • | • |
| 15 × 2,5 mm | – | • | • | • | • | • |
| 24 × 3,0 mm | – | • | • | • | • | • |
Ø 15 and Ø 24 mm are available from 530 mm. Shorter lengths are cut from the next larger standard tube.
Order example
RKR-C799-3-4-1-1
Ø 15 × 2.5 mm, L = 1,030 mm, C 799, works certificate 2.2
Data sheets and operating instructions in the download centre
Typical industries
The assignment names the most common applications and does not exclude others — talk to us if your application is not listed.
Energy, power plants & hydrogen
Furnaces, heat treatment, glass & foundry
Semiconductors, vacuum & electronics
Metal tube up to +1,250 °C: RMR-A · RMR-C · Complete high-temperature thermocouple: TSM und TSK · All designs: Thermowells
Download data sheet RKR-C799 (PDF) →
Dimension drawing, technical data and the complete order key on two pages.
Please contact us
We are glad to help with questions about products, versions and delivery times.
Dennis Kühne
Phone: +49 6181 504 93 18
Mobile: +49 160 91437153
E-mail: info@ghi-gmbh.de